Cooling Equipment Efficiency Criteria

Air-Source Heat Pumps and Central Air Conditioner
Key Product Criteria

Equipment Specification
Air-Source Heat Pumps >= 8.2 HSPF/ >=14 SEER/ >=11.5 EER* for split systems
>= 8.0 HSPF/ >=14 SEER/ >=11 EER* for single package equipment including gas/electric package units
Central Air Conditioners >=14 SEER/ >=11.5 EER* for split systems
>=14 SEER/ >=11 EER* for single package equipment including gas/electric package units

*Energy Efficiency Ratio

Air-Source Heat Pump (ASHP):

An air-source unitary heat pump model consists of one or more factory-made assemblies which normally include an indoor conditioning coil(s), compressor(s), and outdoor coil(s), including means to provide a heating function. ASHPs shall provide the function of air heating with controlled temperature, and may include the functions of air-cooling, air-circulation, air-cleaning, dehumidifying or humidifying.

Central Air Conditioner:

A central air conditioner model consists of one or more factory-made assemblies which normally include an evaporator or cooling coil(s), compressor(s), and condenser(s). Central air conditioners provide the function of air-cooling and may include the functions of air-circulation, air-cleaning, dehumidifying or humidifying.

Heating Seasonal Performance Factor (HSPF):

This is a measure of a heat pump's energy efficiency over one heating season. It represents the total heating output of a heat pump (including supplementary electric heat) during the normal heating season (in Btu) as compared to the total electricity consumed (in watt-hours) during the same period. HSPF is based on tests performed in accordance with ARI 210/2401.

Seasonal Energy Efficiency Ratio (SEER):

This is a measure of equipment energy efficiency over the cooling season. It represents the total cooling of a central air conditioner or heat pump (in Btu) during the normal cooling season as compared to the total electric energy input (in watt-hours) consumed during the same period. SEER is based on tests performed in accordance with ARI 210/2401.

Energy Efficiency Ratio (EER):

This is a measure of the instantaneous energy efficiency of cooling equipment. EER is the steady-state rate of heat energy removal (e.g., cooling capacity) by the equipment in Btuh divided by the steady-state rate of energy input to the equipment in watts. This ratio is expressed in Btuh per watt (Btuh/watt). EER is based on tests performed in accordance with ARI 210/2401.

1Air-Conditioning and Refrigeration Institute. Standard 210/240 "2003 Standard for Unitary Air-Conditioning and Air-Source Heat Pump Equipment."


Energy Star - U.S. Environmental Protection Agency - U.S. Department of Energy

Contact Us
Dew's Comfort Systems
2203 Highway 17 South, Ste 2
North Myrtle Beach, SC 29582
Hours
Monday:
9:00 AM to 4:30 PM
Monday:
9:00 AM to 4:30 PM
Tuesday:
9:00 AM to 4:30 PM
Wednesday:
9:00 AM to 4:30 PM
Friday:
9:00 AM to 4:30 PM
Saturday:
9:00 AM to 12:00 PM
Sunday:
closed
For Heater replacement in North Myrtle Beach SC, opt for an ACCA member.
Dew's Comfort Systems belongs to the Home Builders Association of South Carolina.
Dew's Comfort Systems belongs to the National Association of Home Builders.
For your Heater repair in North Myrtle Beach SC, choose a North Myrtle Beach chamber of commerce member.
Dew's Comfort Systems belongs to the South Carolina Association of Licensed Trades.
Dew's Comfort Systems belongs to the Horry Georgetown Home Builders Association.
Dew's Comfort Systems belongs to Service Roundtable.
Dew's Comfort Systems belongs to Service Nation Alliance